Posted in: Ingredient Buyer Guides
Quick answer: MK-7 assay and all-trans percentage may use different denominators. The MK-7 content of a supplied powder or oil is not the same as the all-trans share of its MK-7 fraction. Multiply the two only when the documents explicitly establish compatible mass-based quantities. If an assay already measures all-trans MK-7 in the supplied preparation, do not apply the isomer proportion a second time.
This guide helps ingredient buyers and formulation teams read a Vitamin K2 (MK-7) specification before preparing a purchasing or blending worksheet. An MK-7 assay should identify the concentration basis separately from the all-trans proportion. GNB’s product page distinguishes concentration, isomer profile and carrier composition. The examples below explain that distinction mathematically; they do not describe a current GNB grade, recommend a serving amount or establish finished-product performance.
Write down the denominator before using a percentage
Start with the exact measurand: what substance is being measured, in what material and on what basis? A result may describe total MK-7 per mass of supplied preparation, all-trans MK-7 per mass of preparation, or an isomer proportion within a defined MK-7 fraction. Ask whether the percentage is a quantitative mass fraction or a chromatographic area percentage. A purity or area statement alone does not establish the active concentration of a carrier-containing powder.
Request the method revision, units, reporting basis and relevant isomer controls for each MK-7 assay. Confirm whether a result refers to the as-supplied or dried material. Do not combine a dried-basis content with an as-supplied ingredient weight without a justified conversion. If the analytical report leaves these questions open, obtain clarification before calculating a purchase requirement. For broader nutrient context, the NIH Office of Dietary Supplements Vitamin K fact sheet identifies menaquinones among vitamin K forms; it is not a raw-material assay method.
Use the appropriate calculation route
Route A: total MK-7 concentration and a compatible all-trans mass share are both documented. Let C be the total MK-7 mass fraction in the supplied preparation, and T the all-trans mass fraction of that total MK-7. Then the all-trans mass fraction of the preparation is C multiplied by T. Convert percentages to decimal fractions first.
Route B: the supplied-preparation MK-7 assay already quantifies all-trans MK-7. Use that documented concentration directly. Applying an isomer percentage again would count the same adjustment twice.
Route C: the report gives only an all-trans proportion or area percentage. The amount per gram of supplied preparation cannot be determined from that number alone. Request the quantitative concentration and an explanation of the analytical basis. Do not assume that an area fraction can be substituted for T without the method’s support.
Three hypothetical COA examples
Training examples only: all values in this table are fictional and illustrate document interpretation. They are not GNB product specifications, available grades or order commitments.
| Hypothetical document wording | Worksheet treatment | Calculated all-trans amount |
|---|---|---|
| A: total MK-7 is 0.20% w/w of the supplied preparation; all-trans is 90% by mass of that total MK-7 | 0.002 multiplied by 0.90 equals 0.0018 of the supplied mass. | 0.18% w/w, equivalent to 1.8 mg/g or 1,800 micrograms/g. |
| B: all-trans MK-7 assay is 0.20% w/w of the supplied preparation | Use the reported all-trans concentration directly; do not apply the isomer adjustment again. | 2.0 mg/g or 2,000 micrograms/g. |
| C: all-trans is reported as 98% chromatographic area, with no quantitative concentration of the preparation | Hold the mass calculation and request the missing concentration and method explanation. | Not determinable from this statement alone. |
The 90% in example A has a different denominator from the 0.20%. The 98% in example C must not be entered as if 98% of the entire supplied powder were all-trans MK-7. Keep the original wording beside each worksheet input so a reviewer can see why a route was chosen.
Check MK-7 assay units with a batch-size example
One percent by mass equals 10 mg/g, or 10,000 micrograms/g. For example A, 0.18% therefore equals 1.8 mg/g. A hypothetical 100 g quantity of that preparation would contain a calculated 180 mg of all-trans MK-7 at the stated input values: 100 g multiplied by 1.8 mg/g.
For a nominal requirement R in milligrams and a documented concentration K in milligrams per gram, the required preparation mass in grams is R divided by K. This is a material-balance calculation, not a recommended intake or an instruction to release a production blend. Use qualified input data and independent checking, particularly when translating between grams, milligrams and micrograms.

Separate content arithmetic from blend and stability evidence
A correct mass calculation does not prove that a small addition will distribute uniformly through a blend. Assess weighing capability, a suitable dilution or premixing procedure, transfer losses and representative sampling under your approved manufacturing controls. Confirm carrier composition and compatibility with the intended process before treating two preparations as interchangeable.
Likewise, a raw-material release assay does not establish retained content over the shelf life of a finished formula. GNB’s product guidance calls for evaluation of the carrier matrix, packaging, storage and mineral-containing systems. For dietary supplement manufacturing controls, consult the applicable 21 CFR Part 111 requirements; they do not provide a conversion from an all-trans percentage to an ingredient assay. Request relevant evidence and test the actual formulation. Any overage requires a justified, approved basis; do not insert an arbitrary percentage to compensate for uncertain handling or stability.
Use a short approval worksheet for each MK-7 assay and supplier offer
- Identify the material. Record the offered grade, lot, carrier composition and specification revision.
- Copy the assay wording. Keep the measurand, numerical value, units and as-supplied or dried basis together.
- Define the isomer statement. Identify its denominator and whether it is mass-based, area-based or another stated calculation.
- Select the route. Document why multiplication is appropriate, unnecessary or not supported.
- Check the result. Have a second reviewer reconcile units and calculations before translating them into a purchase or production requirement.
Compare the lot COA with the agreed specification, and use the sample evaluation checklist for process trials. A higher all-trans proportion alone does not establish a higher concentration in the supplied preparation or a better overall manufacturing proposal.
What to ask in an MK-7 technical RFQ
Please identify the exact offered MK-7 preparation and carrier composition. State whether the assay quantifies total MK-7 or all-trans MK-7, its concentration in the supplied material, units, reporting basis and method. Explain the denominator and analytical basis of the all-trans percentage. Provide the current specification and applicable lot COA, relevant isomer controls, and available stability and handling information for our intended process.
Send your quantity, destination and sample requirements through the B2B quote request. Confirm current packaging, MOQ, sample availability and lead time for the proposed grade rather than inferring commercial terms from an assay example.
Frequently asked questions
Is 98% all-trans the same as 98% MK-7 in a powder?
No. An all-trans statement may describe only an isomer proportion or chromatographic area. Establish the denominator and quantitative concentration of the supplied preparation before calculating an amount per gram.
When can total MK-7 concentration be multiplied by the all-trans share?
Only when the documents establish compatible mass-based quantities, a matching reporting basis and the defined all-trans share of that total MK-7. Obtain method clarification if a proportion is reported on another basis.
Should an all-trans assay be adjusted for the all-trans proportion again?
Not when the assay already quantifies all-trans MK-7 in the supplied preparation on the required basis. Applying the same adjustment again would double-count it.
Does the calculated ingredient amount prove blend uniformity or shelf-life content?
No. The arithmetic gives a nominal material amount from the documented inputs. Blend uniformity, process recovery and retained finished-product content require separate validation and evidence.