This test report guide helps botanical ingredient buyers review pesticide, ethylene oxide (ETO) and polycyclic aromatic hydrocarbon (PAH) results before supplier qualification. A third-party report is useful only when its sample identity, test scope, method, limits and batch link are clear.

Why a test report guide matters to ingredient buyers
A supplier specification describes the agreed quality requirements; a third-party analytical report records results for an identified sample under a stated method. These documents answer different questions. A practical test report guide keeps the requirement, method and lot evidence together. Review both documents and confirm the tested sample represents the material and lot under commercial consideration.
Reports may use different analyte panels, methods, units and reporting limits. A result reported as “not detected” does not mean absolute zero: it means the analyte was not detected above the method’s stated detection or reporting threshold. Ask the laboratory or qualified regulatory team when a result is close to a buyer limit.
Seven checks in this test report guide for pesticide, ETO and PAH results
1. Match the sample to the material and lot
Check the product name, botanical identity where relevant, sample code, lot or batch number, sampling date and report number. Resolve spelling or identifier differences before treating the report as evidence for a purchase lot.
2. Confirm the test panel covers the requested analytes
“Pesticide tested” is not a complete scope description. Review the named compounds and panel coverage. For ETO, check whether the report lists ethylene oxide, 2-chloroethanol or a defined sum. For PAHs, identify each compound tested and whether a reported total is calculated from a specified group.
3. Read the method, laboratory and report date
Record the analytical method, laboratory identity, issue date and any accreditation or scope information shown on the document. Confirm with your quality team that the method is suitable for the analyte, matrix and market requirement; a laboratory name alone does not establish scope suitability.
4. Check units, detection limits and qualifiers
Compare like with like: mg/kg and µg/kg are not interchangeable without conversion. Note the limit of detection (LOD), limit of quantification (LOQ) or reporting limit, plus qualifiers such as “<LOQ.” Do not compare a non-detect with a numerical limit until the reporting basis is understood.
5. Use the correct market reference
Applicable limits depend on product classification, intended use, destination and current rules. The European Commission’s EU Pesticides Database is a reference for checking EU pesticide maximum residue levels; verify the relevant commodity and legal context with qualified personnel. It is not a substitute for checking requirements in other markets.
6. Review ETO and PAH definitions separately
For ETO and PAHs, confirm the applicable analyte definition, calculation basis and specification before interpreting a result. The EU contaminants regulation (Commission Regulation (EU) 2023/915) provides legal context for certain contaminants in food. Applicability to a specific ingredient or use must be assessed against the current consolidated rules and product classification.
7. Link the report to the purchasing decision
Establish whether the report is sample-specific, batch-specific, pooled or historical. Request the current batch COA and confirm document dates, product specification and lot linkage before release. File the report with the reviewed specification and record open questions for the supplier’s quality team. Use this test report guide to capture the review and assign follow-up actions.
Buyer checklist before accepting a report
Use this test report guide as a first-pass screen, then have the responsible quality or regulatory team assess market-specific requirements.
- Product identity and sample or lot identifiers match the commercial material.
- The analyte panel includes the compounds required by the buyer.
- Method, laboratory, report date and any stated accreditation scope are recorded.
- Units, LOD/LOQ, qualifiers and calculation basis are understood.
- Results are assessed against the correct destination-market specification.
- ETO and PAH definitions are checked independently from pesticide results.
- The report is linked to a current COA and the relevant purchasing lot.
How GoodNutrition supports document review
GoodNutrition helps buyers review product specifications, batch COAs and applicable third-party documentation during ingredient evaluation. This test report guide is a buyer-side review aid, not a substitute for applicable specifications or qualified review. Start with our quality control page or contact the team with the ingredient name, specification range, target market and intended application. For more sourcing context, see our Botanical Extract Testing Guide and Supplier Evaluation Checklist.
Frequently asked questions
Does a third-party report guarantee every batch is the same?
No. The report describes the sample identified in that document. Batch COAs and ongoing controls help buyers assess later lots and supply continuity. This test report guide applies to the identified sample, not every future batch.
Should I request reports before or after sampling?
Review available reports during early supplier evaluation, then confirm batch-specific documents for the lot being purchased. If a report predates the lot, ask the supplier to clarify its relationship to the current material. A test report guide works best when the lot link is explicit.
Can GoodNutrition provide ETO, pesticide or PAH reports for a product?
Document availability depends on the ingredient, batch, destination market and current records. Share the product name, specification and application so the team can confirm the documents relevant to your review.